DAM: Direct Angle Measurement Technology for Inclination Measurement

DAM: Direct Angle Measurement Technology for Inclination Measurement

Physical principle, sensing element design, and the technology behind MELDOR DAM.

Most modern MWD/LWD inclination measurement systems use accelerometers to determine the wellbore inclination angle (zenith angle). MELDOR proposes a new approach to this task: the use of a Direct Angle Measurement (DAM) inclinometer based on liquid capacitive sensing elements.

This article explains the physical principle behind this measurement approach, the design of the measurement chamber, and the key engineering factors that affect instrument performance. As an example, we will examine the DAM inclinometer incorporated into the MELDOR directional module.

1. Physical Principle of Measurement

The core of a liquid capacitive inclinometer is a sealed cylindrical chamber partially filled with a liquid dielectric.

In the MELDOR DAM design, the chamber is filled to approximately 50% of its internal volume.

When the chamber changes its orientation relative to the gravitational field, the liquid redistributes inside it. Under static conditions, the liquid’s free surface tends to align perpendicular to the direction of the gravitational acceleration vector.

As a result, the position of the boundary between the liquid and gas phases changes relative to the chamber housing.

This change is used to measure inclination. Since the liquid and gas have significantly different dielectric properties, their redistribution within the electric field changes the electrical capacitance.

Thus, rather than measuring acceleration with an accelerometer, the system detects changes in capacitance caused by the movement of the liquid dielectric inside the chamber.

2. Capacitive Measurement System and Electrode Configuration of the DAM Inclinometer

To understand the operating principle, let us consider a simplified parallel-plate capacitor model.

Its capacitance is defined by the following expression:

C = ε₀ × εᵣ × A / d

where:

  • C — electrical capacitance;
  • ε₀ — vacuum permittivity;
  • εᵣ — relative permittivity of the dielectric medium;
  • A — electrode area;
  • d — distance between the electrodes.

In the measurement chamber, the space between the electrodes is partially filled with liquid and partially with gas.

For a simplified description, the total area of one measurement channel can be represented as the sum of two regions: one occupied by liquid and the other by gas.

The capacitance of the channel can then be approximated as:

Cᵢ = (ε₀ / d) × (εᵣ,l × Aᵢ,l + εᵣ,g × Aᵢ,g)

where:

  • Cᵢ — capacitance of the i-th measurement channel;
  • εᵣ,l — relative permittivity of the liquid;
  • εᵣ,g — relative permittivity of the gas;
  • Aᵢ,l — area of the channel occupied by liquid;
  • Aᵢ,g — area of the channel occupied by gas;
  • d — distance between the electrodes.

The total area of the corresponding channel remains constant:

Aᵢ = Aᵢ,l + Aᵢ,g

As the chamber tilts, the liquid redistributes, changing the areas occupied by the liquid and gas. This, in turn, changes the capacitance of the channel.

Assuming the electrode geometry remains unchanged, the capacitance variation can be expressed within this simplified model as:

ΔCᵢ = (ε₀ / d) × (εᵣ,l − εᵣ,g) × ΔAᵢ,l

This relationship illustrates the physical basis of the measurement: the change in capacitance is related to the change in the area occupied by the liquid and the difference between the dielectric permittivities of the two media.

Electrode Configuration of the DAM Inclinometer

The measurement chamber of the DAM inclinometer uses four independent measurement channels.

Контент статьи             

Рис.1 DAM Inclinometer chamber design

Four sector-shaped electrodes are located on one end face of the cylindrical chamber. Each electrode occupies a 90° sector of the circumference. A single common electrode is located on the opposite end face.

Thus, each sector electrode forms a separate capacitive channel with the common electrode.

As the chamber changes its orientation, the liquid redistributes inside it, and the capacitances of the four channels change according to the new distribution of the liquid and gas phases.

Joint processing of the signals from all four channels makes it possible to determine the orientation of the chamber relative to the gravitational field.

The formulas above describe a simplified physical model of the process. The actual electric field inside a cylindrical chamber has a more complex three-dimensional structure. The real relationship between capacitance and liquid position is also affected by fringing fields, electrode geometry, and parasitic capacitances. Therefore, the final characteristics of the sensing element are established through design calculations, physical implementation, and experimental calibration.

3. Engineering and Manufacturing Considerations

Despite the relatively straightforward physical principle, developing a high-precision liquid capacitive sensing element involves several significant engineering challenges.

Chamber Filling Accuracy

One of the most important parameters is the volume of liquid inside the chamber. In the MELDOR DAM design, it is approximately 50% of the chamber’s internal volume.

Any deviation from this value affects the liquid distribution inside the chamber and, consequently, the characteristics of the measurement channels.

A precise filling and volume-control process is therefore essential to ensure consistent performance across individual sensing elements.

Geometric Accuracy

The geometric parameters of the chamber directly affect the electrical characteristics of the sensing element.

The most important parameters include:

  • internal diameter and length of the chamber;
  • geometry of the internal cavity;
  • electrode position and dimensions;
  • distance between the opposing electrodes;
  • accuracy of the relative positioning of structural components.

Even small deviations can affect nominal capacitance, sensitivity, and the shape of the measurement response. Therefore, both the manufacturing accuracy of an individual chamber and the geometric repeatability across a production batch are important.

Liquid Properties

The liquid is an integral part of the measurement system. Its properties directly influence measurement dynamics and stability.

The most important parameters include:

  • dielectric permittivity;
  • viscosity;
  • surface tension;
  • temperature stability;
  • coefficient of thermal expansion.

Viscosity affects how quickly the liquid redistributes after a change in chamber orientation. Surface tension and wetting properties influence the shape of the free surface and the liquid’s behavior near the chamber walls.

Dielectric properties determine the magnitude of the capacitance change, while the temperature characteristics of the liquid and chamber materials affect parameter stability over the operating temperature range.

Calibration

Even with high manufacturing accuracy, it is impossible to eliminate all individual variations between sensing elements.

Calibration is therefore an essential part of the technology. It accounts for the actual characteristics of each individual chamber and helps achieve the required measurement accuracy.

4. From a Sensing Element to a Three-Axis DAM Inclinometer

A single measurement chamber provides inclination measurement along only one measurement axis.

The DAM inclinometer incorporated into the MELDOR directional module uses three independent liquid capacitive sensing elements, one for each measurement axis.

Рис.2 3-axis DAM inclinometer

Рис.2 3-axis DAM inclinometer

Joint processing of the signals from these elements makes it possible to determine the spatial orientation of the module, including its zenith angle.

Unlike the conventional accelerometer-based approach, determining the zenith angle does not require extracting the gravitational component from accelerometer signals. The measurement is based directly on the position of the liquid inside the sensing chambers.

It is important to note, however, that the liquid’s free surface aligns relative to the effective acceleration vector. Therefore, under dynamic conditions involving vibration, acceleration, and rotation, the measurement conditions may differ from those under static conditions. These effects must be considered when designing and evaluating the system.

Conclusion

DAM is MELDOR’s new approach to inclination measurement in MWD/LWD systems, based on the direct measurement of angles using liquid capacitive sensing elements.

The accuracy of such a system depends not only on its electrical circuitry but also on a combination of mechanical and manufacturing factors: chamber geometry, filling accuracy, liquid properties, material stability, and calibration quality.

MELDOR implements this principle in a three-axis DAM inclinometer incorporated into its directional module.

MELDOR DAM — Direct Angle Measurement. A new approach to inclination measurement in MWD/LWD.